CVE-2020-5807

Published: Dic 29, 2020 Last Modified: Nov 21, 2024 EU-VD ID: EUVD-2020-26964 Aliases: GSD-2020-5807
ExploitDB:
Other exploit source:
Google Dorks:
HIGH 7,5
Attack Vector: network
Attack Complexity: low
Privileges Required: none
User Interaction: none
Scope: unchanged
Confidentiality: none
Integrity: none
Availability: high
MEDIUM 5,0
Access Vector: network
Access Complexity: low
Authentication: none
Confidentiality: none
Integrity: none
Availability: partial

Description

AI Translation Available

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.

EPSS (Exploit Prediction Scoring System)

Trend Analysis

EPSS (Exploit Prediction Scoring System)

Prevede la probabilità di sfruttamento basata su intelligence sulle minacce e sulle caratteristiche della vulnerabilità.

EPSS Score
0,0059
Percentile
0,7th
Updated

EPSS Score Trend (Last 90 Days)

755

Improper Handling of Exceptional Conditions

Incomplete
Common Consequences
Security Scopes Affected:
Other
Potential Impacts:
Other
Applicable Platforms
All platforms may be affected
View CWE Details
Application

Factorytalk Diagnostics by Rockwellautomation

Version Range Affected
To 6.11 (inclusive)
cpe:2.3:a:rockwellautomation:factorytalk_diagnostics:*:*:*:*:*:*:*:*
Common Platform Enumeration - Standardized vulnerability identification
https://www.tenable.com/security/research/tra-2020-71