CVE-2021-43550

Published: Dic 27, 2021 Last Modified: Nov 21, 2024 EU-VD ID: EUVD-2021-30479 Aliases: GSD-2021-43550
ExploitDB:
Other exploit source:
Google Dorks:
MEDIUM 5,9
Attack Vector: adjacent_network
Attack Complexity: high
Privileges Required: none
User Interaction: none
Scope: unchanged
Confidentiality: high
Integrity: low
Availability: none
LOW 3,3
Access Vector: adjacent_network
Access Complexity: low
Authentication: none
Confidentiality: partial
Integrity: none
Availability: none

Description

AI Translation Available

The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.

EPSS (Exploit Prediction Scoring System)

Trend Analysis

EPSS (Exploit Prediction Scoring System)

Prevede la probabilità di sfruttamento basata su intelligence sulle minacce e sulle caratteristiche della vulnerabilità.

EPSS Score
0,0004
Percentile
0,1th
Updated

EPSS Score Trend (Last 90 Days)

327

Use of a Broken or Risky Cryptographic Algorithm

Draft
Common Consequences
Security Scopes Affected:
Confidentiality Integrity Accountability Non-Repudiation
Potential Impacts:
Read Application Data Modify Application Data Hide Activities
Applicable Platforms
Languages: Not Language-Specific, Verilog, VHDL
Technologies: Not Technology-Specific, ICS/OT
View CWE Details
Operating System

Efficia Cm Firmware by Philips

cpe:2.3:o:philips:efficia_cm_firmware:4.0:*:*:*:*:*:*:*
Common Platform Enumeration - Standardized vulnerability identification
Application

Patient Information Center Ix by Philips

cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*
Common Platform Enumeration - Standardized vulnerability identification
Operating System

Efficia Cm Firmware by Philips

Version Range Affected
From a.01 (inclusive)
To c.0x (inclusive)
cpe:2.3:o:philips:efficia_cm_firmware:*:*:*:*:*:*:*:*
Common Platform Enumeration - Standardized vulnerability identification
Application

Patient Information Center Ix by Philips

cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*
Common Platform Enumeration - Standardized vulnerability identification
https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02
Third Party Advisory US Government Resource
https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02
https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02
Third Party Advisory US Government Resource
https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02